Title: TESTING AND EVALUATION OF MERRITT PARKWAY GUIDERAIL
Accession Number: 00743629
Record Type: Component
Record URL: Availability: Find a library where document is available Abstract: A blocked-out steel-backed timber guiderail and transition on steel posts were successfully developed and crash-tested in accordance with requirements set forth in NCHRP Report 350 for Test Level 3. The timber guiderail system was developed for placement along the scenic Merritt Parkway in Connecticut. The timber guiderail and transition were constructed from rough-sawn commercial Grade 1 southern pine backed with a 10- x 152-mm ASTM A588 Grade 50 structural steel plate. The guiderail was supported by W150 x 22.5 steel posts 2 m long, spaced 3.05 m through the length-of-need section. Reduced post spacings of 0.8 m and 1.5 m were used in the transition section.
Supplemental Notes: This paper appears in Transportation Research Record No. 1599, Roadside Safety Features and Other General Design Issues.
Language: English
Corporate Authors: Transportation Research Board 500 Fifth Street, NW Authors: Lohrey, E CCarney III, J FBullard Jr, D LAlberson, D CMenges, W LPagination: p. 40-47
Publication Date: 1997
Serial: ISBN: 0309061709
Features: Figures
(1)
; Photos; References
(1)
; Tables
(1)
TRT Terms: Identifier Terms: Old TRIS Terms: Subject Areas: Design; Highways; Research; Safety and Human Factors; I85: Safety Devices used in Transport Infrastructure
Files: TRIS, TRB, ATRI
Created Date: Dec 11 1997 12:00AM
More Articles from this Serial Issue:
|