Title: SINGLE LIFT CONSTRUCTION WITH HOT PLANT MIX BASE
Accession Number: 00214430
Record Type: Component
Abstract: IN 1963, THE WOODBRIDGE TOWNSHIP ENGINEERING DEPARTMENT RECORDED TEMPERATURES AT REGULAR TIME INTERVALS AND AT VERTICAL INTERVALS OF 1 1/2 INCHES THROUGH BITUMINOUS STABILIZED BASE DURING THE ROLLING PROCEDURE. CORES WERE CUT FROM THE LOCATIONS AND TESTED. THE MIX DESIGN WAS CHANGED TO DETERMINE THE DIFFERENCE IN FINAL COMPACTION OF LIFTS OF DIFFERENT DEPTHS. TEMPERATURES WERE RECORDED WHEN USING THREE DIFFERENT TYPES OF ROLLERS AND TEMPERATURES PLOTTED AGAINST THE VERTICAL POSITION OF THE THERMOCOUPLES IN INCHES ABOVE AND BELOW THE SUBGRADE ELEVATION PRODUCED CURVES SHOWING THE TEMPERATURE CHANGES THROUGH THE BASE VERTICALLY AT SELECTED PERIODS OF ELAPSED TIME. TEMPERATURE IS LOST FROM THE BOTTOM 2 INCHES OF THE BASE DUE TO TRANSMISSION INTO THE SUBGRADE, THE SUBGRADE TEMPERATURE RISES. RESULTS SHOW THAT HOT PLANT MIX BITUMINOUS STABILIZED BASE CAN BE CONSTRUCTED IN A SINGLE LIFT. MIX DESIGN, TEMPERATURE AND THE SELECTION OF COMPACTION EQUIPMENT ARE IMPORTANT FACTORS IN SINGLE LIFT CONSTRUCTION.
Supplemental Notes: No 46, pp 1-29, 13 FIG. Distribution, posting, or copying of this PDF is strictly prohibited without written permission of the Transportation Research Board of the National Academy of Sciences. Unless otherwise indicated, all materials in this PDF are copyrighted by the National Academy of Sciences. Copyright © National Academy of Sciences. All rights reserved.
Authors: Beagle, C WPublication Date: 1966
Serial: Media Type: Digital/other
TRT Terms: Uncontrolled Terms: Old TRIS Terms: Subject Areas: Construction; Highways; Materials
Files: TRIS, TRB
Created Date: Nov 21 1994 12:00AM
|