Abstract:
RESULTS ARE REPORTED FOR 90 COMPACTION RUNS ON SIX TYPICAL A-2 SOILS, ONE PLASTIC AND ONE FRIABLE FROM EACH OF THREE STATES, ALABANA, NORTH CAROLINA, AND VIRGINIA. RUNS WERE MADE USING 0, 0.5, 1, 2, AND 3 PERCENT OF CALCIUM CHLORIDE ADMIXTURE. COMPACTIVE EFFORTS USED WERE 6-IN. DROP WITH THE STANDARD HAMMER, 12-IN. DROP WITH THE STANDARD HAMMER, AND 18-IN. DROP WITH THE 10-LB. HAMMER. OTHER DETAILS OF THE PROCEDURE WERE HELD CONSTANT. THE PROCTOR MOLD WAS USED AND PLASTICITY NEEDLE READINGS WERE TAKEN. THE RESULTS INDICATED THAT A SUBSTANTIAL SAVING IN COMPACTIVE EFFORT REQUIRED TO OBTAIN A SPECIFIED DENSITY IS EFFECTED BY THE ADDITION OF CALCIUM CHLORIDE. FOR SOME SOILS, THE MAXIMUM DENSITY OBTAINED WITHOUT ADMIXTURE WAS REPRODUCED WITH ABOUT 50 PERCENT OF THE COMPACTIVE EFFORT WHEN 3 PERCENT OF ADMIXTURE WAS USED. PENETRATION CURVES INDICATED A NOTICEABLE INCREASE IN WORKABILITY WITH SUCCESSIVE ADDITIONS OF THE CHEMICAL. /AUTHOR/
Supplemental Notes:
Vol 26, pp 594-602, 7 FIG, 5 TAB. Distribution, posting, or copying of this PDF is strictly prohibited without written permission of the Transportation Research Board of the National Academy of Sciences. Unless otherwise indicated, all materials in this PDF are copyrighted by the National Academy of Sciences. Copyright © National Academy of Sciences. All rights reserved.