Title: WICK DRAIN SELECTION AND DESIGN
Accession Number: 00459535
Record Type: Component
Availability: Find a library where document is available Abstract: To ensure predictable performance of a given installation, proper wick selection is very important. The second key to success is a reasonable prediction of the coefficient of consolidation of the soft foundation material to be consolidated. In addition to proper selection, proper spacing, and correct installation, each project should include construction controls on rate of loading, and a detailed instrumentation monitoring program to ensure stability during critical loading periods. This paper also gives details of prefabricated wick drains and the design of such drains.
Supplemental Notes: Transportation Research Circular Number 309, Shared Experience in Geotechnical Engineering: Wick Drains. Distribution, posting, or copying of this PDF is strictly prohibited without written permission of the Transportation Research Board of the National Academy of Sciences. Unless otherwise indicated, all materials in this PDF are copyrighted by the National Academy of Sciences. Copyright © National Academy of Sciences. All rights reserved.
Corporate Authors: Transportation Research Board 500 Fifth Street, NW Authors: HANNON, J BPagination: pp 6-7
Publication Date: 1986-9
Serial: Media Type: Digital/other
Features: References
(9)
TRT Terms: Old TRIS Terms: Subject Areas: Construction; Design; Geotechnology; Highways; Maintenance and Preservation; I42: Soil Mechanics
Files: TRIS, TRB
Created Date: Nov 30 1986 12:00AM